+86-571-88550927
Niski olovni manometar video

Niski olovni manometar

Manometar niskog olova
Accuracy: ±(3-2-3 percent FS), Size: 1½" or 2"
Ovlaženi dijelovi: fosforna bronza, Bourdon cijev i mesing ili puni nehrđajući čelik.
kontaktirajte mjerače za više detalja i tačnu cijenu.

Opis

Manometar niskog olova

Pakovanje Dostava:

Pakovanje: odvojena kutija za papir po jedinici.

Vrsta pakovanja: polister vreća plus papirna kutija, kartonska kutija, paleta.

Težina kartona: 20-25 kg

Vrijeme isporuke: 15-30 dana

Opisi:

Accuracy: ±(3-2-3 percent FS)
Size: 1½" or 2"
Ovlaženi dijelovi: fosforna bronza, Bourdon cijev i mesing
Rasponi: Pritisak - 0 do 300 psi (Molimo kontaktirajte korisničku podršku ako su potrebni drugi rasponi)

LOW LEAD PRESSURE GAUGE


thread size

O nama:

factory figure 1

factory figure 2

Više proizvoda

relatedproducts

Komunikacije:

communications

Certifikati

pressure gauge certificate R

Proizvodnja i inspekcija

pressure gauge factory 4

production process

Nivo tačnosti
1. Ocena tačnosti manometra odražava tačnost prikazane vrednosti bliske stvarnoj vrednosti u poređenju između testiranog manometra i preciznog merača. Ona je jednaka procentu odnosa apsolutne vrijednosti maksimalne osnovne greške prema gornjoj granici mjerenja, koja se utvrđuje prema grešci generisanoj u kalibraciji.
2. China's general industrial pressure gauges are divided into four accuracy levels, which comply with the allowable error of the pressure gauge in the verification regulation of spring tube general pressure gauge, pressure vacuum gauge and vacuum gauge (jjg52-1999). The four accuracy levels are: Level 1, level 1.6, level 2.5 and level 4. The allowable error (calculated as a percentage of the upper limit of measurement) is ± 1 percent , ± 1.6 percent , ± 2.5 percent and ± 4 percent respectively.
3. China's new verification regulation of digital pressure gauge was published and implemented in 2005, which is in line with jjg875-2005 verification regulation of digital pressure gauge. The accuracy of pressure is specified as ± 0.01 percent , ± 0.02 percent , ± 0.05 percent , ± 0.1 percent , ± 0.2 percent , ± 0.5 percent , ± 1.0 percent and ± 1.6 percent respectively.
4. Metoda razumnog izbora stepena tačnosti manometra će se zasnivati ​​na zahtevima proizvodnog procesa, ekonomičnosti i praktičnosti, metodi detekcije itd., a stepen tačnosti se bira prema dozvoljenoj grešci koju zahteva minimalna vrednost izmjerenog pritiska.

Pakovanje i dostava:

packing process


contact us 1

Popularni tagovi: nisko olovni manometar, Kina, dobavljači, proizvođači, fabrika, prilagođeni, veleprodaja, jeftini

Pošaljite upit

(0/10)

clearall